HYGOOD FM 200 PDF

STORAGE CYLINDER. •. Brand: HYGOOD. •. Manufacturer: Macron Safety Systems (UK) Limited. •. Country of Origin: United Kingdom. •. Type: Welded. HYGOOD. FM® Installation Guide///Issue 9. SECTION 2 – SYSTEM COMPONENTS. FM® Container. The agent storage vessel. Electrically non-conductive, FM works by removing heat from a fire so that combustion cannot be sustained. When it comes to being safe for use, FM

Author: Akirr Faedal
Country: Russian Federation
Language: English (Spanish)
Genre: Environment
Published (Last): 22 October 2013
Pages: 253
PDF File Size: 16.57 Mb
ePub File Size: 1.32 Mb
ISBN: 112-6-92997-304-1
Downloads: 40264
Price: Free* [*Free Regsitration Required]
Uploader: Kilrajas

From local workshops to international conferences, Tyco Gas and Flame Detection conducts, attends, and sponsors a variety of events throughout the year. By continuing to navigate through this site or by clicking Accept, you consent to the use of cookies on your device as described in our privacy notice.

Discharge Hjgood Discharge nozzles shall be selected for the use intended and for their discharge characteristics. We have a network of fully authorised distribution partners dedicated to supplying HYGOOD gaseous fire suppression systems. HYGOOD designs and supplies a complete range of gaseous fire suppression solutions to the industrial and commercial markets, through a network of highly trained and authorsied distributors. Sorry, but the version of Internet Explorer you are using is not supported.

To prevent loss of agent through openings to adjacent hazards or work areas, opening shall be permanently sealed or equipped with automatic closures. LED display countdown timer, adjustable from 0 to 90 seconds must hyggood provided for each protected area to indicate the remaining time before actual gas discharge. POG Fire risks in petrochemical, oil and gas POG facilities are most often associated with the storage and transportation areas, where flammable liquids, hydrocarbons or gases are to be found.

Our expert sales team and network of approved distributors have skills and experience in understanding the various fire risk elements within a certain environment and we can advise on the most suitable fire protection solution for your needs.

Hygood FM, Sapphire and i3 Inert gas systems with i-flow technology are a trusted choice in clean agent fire protection, perfectly suited to where disruption has to be minimised and survivability of the business is critical. Our sales and distribution network is committed to supporting customers all over Europe and APAC with project support and advice on tender specification documentation. We understand that loyal support of customers is vital to the success of a business, and it is this thought that underpins every single customer interaction.

Discharge nozzles shall be 2000 in corrosion resistant material and shall be positioned in a manner to effect a uniform concentration hyyood the shortest time after discharge. Each system shall be able to perform independently via the interlocking with the automatic detection system as well as manual actuation under emergency situation. Each container shall be super-pressurised with dry nitrogen to 25 bar at 20 o C and shall be equipped with pressure gauge to indicate the pressure of its content.

  JON ROGAWSKI CALCULO UNA VARIABLE PDF

Hygood | Haven Fire & Safety L.L.C.

HYGOOD is renowned for first class product development, design and ensuring our systems are industry approved. The Contractor shall provide and connect all the necessary controls, relay, cable, conduit, hygoid to effect this interlocking operation. To support specialised fire suppression engineers, we have developed comprehensive information to support engineers who are interested in specifying fire protection systems for commercial and industrial spaces.

View Contact Call Seller Now.

Emerging economies in the global market and continued demand to deliver consumer goods and services from one part of the world to another have all made a significant contribution to the demand for new ships to sail all over the world. The automatic detection system shall comprise cross-zone detection to activate before activation of the gaseous fire suppression system.

The document library contains current data sheets, brochures, industry applications, and white papers. Design Standards The system shall be designed, installed, inspected, maintained, tested and recharged by qualified, trained personnel in accordance with NFPA Hygood on Clean Agent Fire Extinguishing Systems, edition.

Using innovative technology, the iFLOW Fire Suppression System is a state-of-the-art delivery system that provides a regulated and effective discharge of inert gas clean agent. Any material not specifically mentioned in this specification or not shown in the drawings but are required for proper performance and operation shall be included and installed.

Co2 Fire Suppression Systems. They are designed using bespoke software, which accurately calculates the amount of FM required for the protected space.

The panel shall be able to monitor all functions, process all alarm and releasing signals to activate the fire suppression system. Our People Our competitive edge begins with our people and values. Maintenance and Warranty The system shall be warranted for parts and labour for not less than a nygood of one year 12 months from the date of installation.

HYGOOD designs and supplies a complete range of gaseous fire suppression solutions to the industrial and commercial markets, through a network of highly trained and authorsied distributors.

High value facilities warrant dedicated specialist protection. There are numerous fire hazard risks hygoos any power generation facility.

Hygood FM200

The agent shall have no environmental impact i. Control Panel The system shall operate from an output voltage of volts AC, 50 Hz supplied to the power charger module within the control panel. The agent is discharged after a time delay upon detection of fire to warn any occupant to evacuate the room.

  ITEXTSHARP CREATE SEARCHABLE PDF

I agree to the terms and privacy policy. Over pressurization of the container shall be prevented by a safety disc incorporated with the container valve. We help our customers achieve their safety, security and business goals by finding smarter ways to save lives, improve businesses and protect where people live and work. Nature of Business Service Provider. Emerging economies in the global market and continued demand to deliver consumer goods and services from one part of the world to another have all made a significant contribution to the demand for new ships to sail all over the world.

The decision to use FM can be based on a number of key factors: Novec Fire Suppression System in Chennai. To find out how is works click here to watch the video now. This site uses cookies to offer you a better browsing experience. Call Send a quick message.

HYGOOD FM-200® Clean Agent Fire Suppression Systems

Electrically non-conductive, FM works by removing heat from a fire so that hyhood cannot be sustained. Fire risks in petrochemical, oil and gas POG facilities are most often associated with the storage and transportation areas, where flammable liquids, hydrocarbons or gases are to be found.

Please click here to upgrade your browser. HYGOOD FM systems are accepted as providing reliable and effective fire protection solutions for high value assets, 020 and locations, as well as the people who work in these protected areas. HYGOOD gaseous fire suppression solutions have been specifically developed by our experts in fire gm who have analysed and evaluated the fire risk factors associated with each environment to produce the most effective solution.

Our competitive edge begins with our people and values.

Sorry, but the version of Internet Explorer you are using is not supported. Data Centres Are considered critical to business infrastructure, they affect our lives in many ways, from managing the information used to run our cities, to streaming our entertainment and handling the huge amounts of data we produce every day in our working lives.

Upon activation of the gaseous fire suppression system, it shall cut off the operation of the computer air-conditioning units, which are installed hygooc others. Please click here to upgrade your browser.